- Basic extinguisher for class A risks (cubustible materials)
- High performance version for space savings applications
9L Water Extinguisher
 |
| Suitable For: |
Class A (combustibles) only. Not for flammables or electrical risks. |
| Fire Rating: |
13A |
| Duration of Discharge (sec): |
60 |
| Range of Discharge (metres): |
7-8 |
| Charged Weight (kg): |
14.3 |
| Dimensions HxWxD (mm): |
620x290x200 | |
3L Ecospray Extinguisher
 |
| Suitable For: |
Class A (combustibles). Has passed 35kV electrical conductivity test. High fire rating for size makes it ideal for domestic or space saving applications. |
| Fire Rating: |
13A |
| Duration of Discharge (sec): |
30 |
| Range of Discharge (metres): |
4 |
| Charged Weight (kg): |
4.4 |
| Dimensions HxWxD (mm): |
435x275x160 | |
Foamspray Extinguisher
- Multipurpose water based extinguishers
- Have passed extinguisher 35k Velectrical Conductivity test
2 L Foamspray extinguisher
 |
| Suitable For: |
Mixed class A (combustibles) and class B (flammables) risks. Has passed 35kV electrical conductivity test |
| Fire Rating: |
5A, 55B |
| Duration of Discharge (sec): |
20 |
| Range of Discharge (metres): |
2 |
| Charged Weight (kg): |
3.5 |
| Dimensions HxWxD (mm): |
365x152x110 | |
6L Foamspray Extinguisher
 |
| Suitable For: |
Mixed class A (combustibles) and class B (flammables) risks. Has passed 35kV electrical conductivity test |
| Fire Rating: |
13A, 144B |
| Duration of Discharge (sec): |
36 |
| Range of Discharge (metres): |
4-6 |
| Charged Weight (kg): |
10.5 |
| Dimensions HxWxD (mm): |
455x260x200 | |
9L Foamspray Extinguisher
 |
| Suitable For: |
Mixed class A (combustibles) and B (flammabel liquids) risks. Has passed the 35kV electrical conductivity test. |
| Fire Rating: |
21A, 183B |
| Duration of Discharge (sec): |
53 |
| Range of Discharge (metres): |
4-6 |
| Charged Weight (kg): |
14.5
|
| Dimensions HxWxD (mm): |
610x260x200 | |
Dry Powder Extinguisher
- Multipurpose
- High Fire Ratings
1 kg and 2 kg Dry Powder extinguishers - standard
 |
| Suitable For: |
Class A (combustibles), Class B (flammables) and electrical risks. Transport bracket included. |
| Fire Rating: |
5A, 34B / 13A, 89B |
| Duration of Discharge (sec): |
8 / 9.5 |
| Range of Discharge (metres): |
> 4 |
| Charged Weight (kg): |
1.5 / 3.2 |
| Dimensions HxWxD (mm): |
280x135x95 / 408x170x108 | |
1 kg and 2 kg Dry Powder extinguishers - vehicle
 |
| Suitable For: |
Class A (combustibles), Class B (flammables) and electrical risks. Transport bracket included. |
| Fire Rating: |
8A, 34B / 13A, 89B |
| Duration of Discharge (sec): |
8 / 10 |
| Range of Discharge (metres): |
> 4 |
| Charged Weight (kg): |
1.5 / 3.5 |
| Dimensions HxWxD (mm): |
267x90x109 / 315x110x145 | |
4 kg Dry Powder Extinguisher
 |
| Suitable For: |
Class A (combustibles), Class B (flammables) and electrical risks. |
| Fire Rating: |
21A, 113B |
| Duration of Discharge (sec): |
12 |
| Range of Discharge (metres): |
> 6 |
| Charged Weight (kg): |
6.7 |
| Dimensions HxWxD (mm): |
415x310x160 | |
6 kg Dry Powder extinguisher
 |
| Suitable For: |
Class A (combustibles), Class B (flammables) and electrical risks. |
| Fire Rating: |
27A, 144B |
| Duration of Discharge (sec): |
16 |
| Range of Discharge (metres): |
> 6 |
| Charged Weight (kg): |
9.1 |
| Dimensions HxWxD (mm): |
505x285x160 | |
9 kg Dry Powder Extinguisher
 |
| Suitable For: |
Class A (combustibles), Class B (flammables) and electrical risks. |
| Fire Rating: |
43A, 233B |
| Duration of Discharge (sec): |
16 |
| Range of Discharge (metres): |
> 7 |
| Charged Weight (kg): |
13.6 |
| Dimensions HxWxD (mm): |
455x490x160 | |
Carbon Dioxide Extinguishers
- For Class B (flammable liquid) risks
- Safe on electrial risks
- Clean
2 kg CO2 Extinguisher
 |
| Suitable For: |
Class B (flammables) and electrical risks. Not effective on Class A (combustibles) |
| Fire Rating: |
34B |
| Duration of Discharge (sec): |
12 |
| Charged Weight (kg): |
4.75 |
| Dimensions HxWxD (mm): |
490x175x120 | |
5 kg CO2 Extinguisher
 |
| Suitable For: |
Class B (flammables) and electrical risks. Not effective on Class A (combustibles) |
| Fire Rating: |
70B |
| Duration of Discharge (sec): |
23 |
| Charged Weight (kg): |
11.6 |
| Dimensions HxWxD (mm): |
665x190x155 | |
F Class (Wet Chemical) Extinguisher
- Specially developed to tackle modern high temperature cooking oil fires
6 L F Class extinguisher
 |
| Suitable For: |
Specially developed for cooking oil fires (Class F). Also effective on Class A (combustibles) and has passed the 35kV electrical conductivity test. |
| Fire Rating: |
13A, 75F |
| Duration of Discharge (sec): |
>43 |
| Range of Discharge (metres): |
4 |
| Charged Weight (kg): |
11.8 |
| Dimensions HxWxD (mm): |
533x242x180 (without hose and lance) | |
Flammable Metals Extinguisher
- For fires involving Magnesium, Sodium, Potassium, Lithium
image not available
Polished Extinguishers
- Prestige finish for situations where asethetics are important
Polished Extinguishers
 |
| Suitable For: |
A range of polished extinguishers for use in prestige areas |
| Fire Rating: |
various |
| Duration of Discharge (sec): |
various |
| Range of Discharge (metres): |
various |
| Charged Weight (kg): |
various |
| Dimensions HxWxD (mm): |
640x300x180 | |